{"id":6323,"date":"2013-11-16T06:11:22","date_gmt":"2013-11-16T11:11:22","guid":{"rendered":"http:\/\/www.napoleon.cc\/tips\/?p=6323"},"modified":"2021-06-18T16:28:23","modified_gmt":"2021-06-18T16:28:23","slug":"electrical-panels-bathrooms","status":"publish","type":"post","link":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/","title":{"rendered":"Electrical Panels in Bathrooms"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\" id=\"h-electrical-panels-in-bathrooms-are-not-permitted\">Electrical Panels in Bathrooms are Not Permitted<\/h1>\n\n\n\n<p>Many homeowners have electrical work done without having a building permit or an electrical inspection at completion of work.&nbsp; One very unique problem that I have encountered every so often, is a homeowner installing a bathroom where main electrical panel is located.<\/p>\n\n\n\n<p><a href=\"http:\/\/www.napoleon.cc\"><\/a>Most&nbsp;electrical&nbsp;work&nbsp;requires that you pull a permit with your local electrical authority.&nbsp; Many jurisdictions allow a homeowner to work on his\/her own home\u2019s electrical system.&nbsp; Some areas only allow work on branch circuits and not main&nbsp;service&nbsp;panel&nbsp;installation.&nbsp; Other areas will not allow homeowner permits at all.&nbsp; This varies from place to place, so it is CRITICAL that, before you commence any do-it-yourself home wiring project, you first check the rules in your area.<\/p>\n\n\n\n<p><b>Exclusion of Rules<\/b>:&nbsp; If a house had a permit issued, was inspected and met the standard required at that time, it would be considered &#8220;Grandfathered&#8221;, and would not be required to be brought up to today&#8217;s standards.&nbsp; This would not apply to any work that was done improperly or to any additions to electrical system without a permit.<\/p>\n\n\n\n<p><b>According to 2006 Electrical Code Simplified, the following rules apply:<\/b><\/p>\n\n\n\n<p>Rule 2-308 requires a minimum working space of 39 inches of floor space in front of electrical equipment.<\/p>\n\n\n\n<p>Rule 26-402 Location of Panelboards<\/p>\n\n\n\n<p>Subrule (1)&nbsp; Panelboards shall not be located in coal bins, clothes closets, <b>bathrooms<\/b>, stairways, high ambient rooms, dangerous or hazardous locations, nor in any similar undesirable places.<\/p>\n\n\n\n<p><strong>According to the &nbsp;NEC (2011 edition)<\/strong><br>\nSection 230.70(A)(2) &#8211; &#8220;Service disconnecting means shall not be installed in bathrooms.&#8221;<br>\nSection 240.24(E) &#8211; &#8220;In dwelling units, dormitories, and guest rooms or guest suites, over current devices, other than supplementary over current protection, shall not be located in bathrooms.&#8221;<\/p>\n\n\n\n<p>This is from Ontario Electrical Safety Bulletins 2009<\/p>\n\n\n\n<p>BULLETIN 26-20-2<\/p>\n\n\n\n<p>Panel boards \u2013 Location, Working Space and Mounting Height<\/p>\n\n\n\n<p>Rules 26-402, 2-308, 2-310 and 6-206<\/p>\n\n\n\n<p>Issued May 2009<\/p>\n\n\n\n<p>Supersedes Bulletin 26-20-1<\/p>\n\n\n\n<p><b>Scope <\/b><\/p>\n\n\n\n<p>(1) Mounting height of a Panelboard<\/p>\n\n\n\n<p>(2) Working space around a panelboard<\/p>\n\n\n\n<p>(3) Panelboards and bathrooms<\/p>\n\n\n\n<p>Rules 6-206 and 26-402 give direction as to where an electrical panelboard should not be installed by<\/p>\n\n\n\n<p>noting some of the undesirable places. An important part of this requirement is to also insure ready<\/p>\n\n\n\n<p>access to the panelboard and to provide suitable working space for operation or maintenance as required<\/p>\n\n\n\n<p>by Rules 2-308 and 2-310.<\/p>\n\n\n\n<p>(1) Mounting height of a Panelboard<\/p>\n\n\n\n<p><b>Direction <\/b><\/p>\n\n\n\n<p>There has been some confusion in the industry regarding interpretation of Rule 26-402(2) with respect to<\/p>\n\n\n\n<p>the correct mounting height of a panelboard in a dwelling unit. This subrule has two criteria that must be met:<\/p>\n\n\n\n<p>1. The panel shall be mounted as high as possible.<\/p>\n\n\n\n<p>2. No circuit breaker handle or breaker blank shall be more than 1.7 m above the finished floor level.<\/p>\n\n\n\n<p>(2) Working space around a panelboard<\/p>\n\n\n\n<p><b>Question<br>\n<\/b>What is meant by &#8220;A minimum working space of 1 m with secure footing&#8230;&#8221; when applied to residential panel boards that are mounted on or in a wall and require access from only the front? <b><\/b><\/p>\n\n\n\n<p><b>Direction<br>\n<\/b>This is interpreted as meaning a space that is at least 2 m in height, at least 1 m in depth in front of the panel, and at least 1 m in width or the width of the panel board, whichever is greater. The panel board does not have to be centered in the width of the working space; it can be off center.<\/p>\n\n\n\n<p>(3) Panelboards and bathrooms<\/p>\n\n\n\n<p><b>Background <\/b><\/p>\n\n\n\n<p>Questions periodically arise about installing a panelboard in a bathroom. This is considered an undesirable location because of excessive moisture issues and limited working space in front of the electrical panel in many bathrooms.<\/p>\n\n\n\n<p><b>&nbsp;Direction <\/b><\/p>\n\n\n\n<p>If the panelboard were installed in a \u201cseparate room\u201d located off of the bathroom, that provides the one square meter of clear working space as required by Rule 2-308, as well as ready access to the door leading into the room as per Rule 2-310, then the panelboard would be considered to be located in an acceptable location.<\/p>\n\n\n\n<p>Check back often to see more information as this article is updated as information becomes available.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Electrical Panels in Bathrooms are Not Permitted Many homeowners have electrical work done without having a building permit or an electrical inspection at completion of work.&nbsp; One very unique problem that I have encountered every so often, is a homeowner installing a bathroom where main electrical panel is located. Most&nbsp;electrical&nbsp;work&nbsp;requires that you pull a permit [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"1500","footnotes":""},"categories":[13,21],"tags":[],"class_list":["post-6323","post","type-post","status-publish","format-standard","hentry","category-electrical","category-home-inspection"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Electrical Panels in Bathrooms by Barrie Home Inspector<\/title>\n<meta name=\"description\" content=\"Electrical Panels in Bathrooms by Barrie Home Inspector.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electrical Panels in Bathrooms by Barrie Home Inspector\" \/>\n<meta property=\"og:description\" content=\"Electrical Panels in Bathrooms by Barrie Home Inspector.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/\" \/>\n<meta property=\"og:site_name\" content=\"Barrie Home Inspector Tips\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Barrie-Home-Inspector-50665344913\/\" \/>\n<meta property=\"article:published_time\" content=\"2013-11-16T11:11:22+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-06-18T16:28:23+00:00\" \/>\n<meta name=\"author\" content=\"Roger Frost\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@homeinspection\" \/>\n<meta name=\"twitter:site\" content=\"@homeinspection\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/electrical-panels-bathrooms\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/electrical-panels-bathrooms\\\/\"},\"author\":{\"name\":\"Roger Frost\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#\\\/schema\\\/person\\\/b87f223889d916ee48b916377bdeacb0\"},\"headline\":\"Electrical Panels in Bathrooms\",\"datePublished\":\"2013-11-16T11:11:22+00:00\",\"dateModified\":\"2021-06-18T16:28:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/electrical-panels-bathrooms\\\/\"},\"wordCount\":691,\"articleSection\":[\"Electrical Inspections\",\"Home Inspection\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/electrical-panels-bathrooms\\\/\",\"url\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/electrical-panels-bathrooms\\\/\",\"name\":\"Electrical Panels in Bathrooms by Barrie Home Inspector\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#website\"},\"datePublished\":\"2013-11-16T11:11:22+00:00\",\"dateModified\":\"2021-06-18T16:28:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#\\\/schema\\\/person\\\/b87f223889d916ee48b916377bdeacb0\"},\"description\":\"Electrical Panels in Bathrooms by Barrie Home Inspector.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/electrical-panels-bathrooms\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/napoleon.cc\\\/tips\\\/electrical-panels-bathrooms\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/electrical-panels-bathrooms\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Panels in Bathrooms\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#website\",\"url\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/\",\"name\":\"Barrie Home Inspector Tips\",\"description\":\"Home Owner &amp; Home Buyer Tips - Valuable Resource to Help Protect your Home\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#\\\/schema\\\/person\\\/b87f223889d916ee48b916377bdeacb0\",\"name\":\"Roger Frost\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g\",\"caption\":\"Roger Frost\"},\"sameAs\":[\"https:\\\/\\\/www.napoleon.cc\\\/tips\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Electrical Panels in Bathrooms by Barrie Home Inspector","description":"Electrical Panels in Bathrooms by Barrie Home Inspector.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/","og_locale":"en_US","og_type":"article","og_title":"Electrical Panels in Bathrooms by Barrie Home Inspector","og_description":"Electrical Panels in Bathrooms by Barrie Home Inspector.","og_url":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/","og_site_name":"Barrie Home Inspector Tips","article_publisher":"https:\/\/www.facebook.com\/Barrie-Home-Inspector-50665344913\/","article_published_time":"2013-11-16T11:11:22+00:00","article_modified_time":"2021-06-18T16:28:23+00:00","author":"Roger Frost","twitter_card":"summary_large_image","twitter_creator":"@homeinspection","twitter_site":"@homeinspection","twitter_misc":{"Written by":false,"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/#article","isPartOf":{"@id":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/"},"author":{"name":"Roger Frost","@id":"https:\/\/napoleon.cc\/tips\/#\/schema\/person\/b87f223889d916ee48b916377bdeacb0"},"headline":"Electrical Panels in Bathrooms","datePublished":"2013-11-16T11:11:22+00:00","dateModified":"2021-06-18T16:28:23+00:00","mainEntityOfPage":{"@id":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/"},"wordCount":691,"articleSection":["Electrical Inspections","Home Inspection"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/","url":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/","name":"Electrical Panels in Bathrooms by Barrie Home Inspector","isPartOf":{"@id":"https:\/\/napoleon.cc\/tips\/#website"},"datePublished":"2013-11-16T11:11:22+00:00","dateModified":"2021-06-18T16:28:23+00:00","author":{"@id":"https:\/\/napoleon.cc\/tips\/#\/schema\/person\/b87f223889d916ee48b916377bdeacb0"},"description":"Electrical Panels in Bathrooms by Barrie Home Inspector.","breadcrumb":{"@id":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/napoleon.cc\/tips\/electrical-panels-bathrooms\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/napoleon.cc\/tips\/"},{"@type":"ListItem","position":2,"name":"Electrical Panels in Bathrooms"}]},{"@type":"WebSite","@id":"https:\/\/napoleon.cc\/tips\/#website","url":"https:\/\/napoleon.cc\/tips\/","name":"Barrie Home Inspector Tips","description":"Home Owner &amp; Home Buyer Tips - Valuable Resource to Help Protect your Home","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/napoleon.cc\/tips\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/napoleon.cc\/tips\/#\/schema\/person\/b87f223889d916ee48b916377bdeacb0","name":"Roger Frost","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g","caption":"Roger Frost"},"sameAs":["https:\/\/www.napoleon.cc\/tips"]}]}},"_links":{"self":[{"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/posts\/6323","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/comments?post=6323"}],"version-history":[{"count":0,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/posts\/6323\/revisions"}],"wp:attachment":[{"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/media?parent=6323"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/categories?post=6323"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/tags?post=6323"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}