{"id":217,"date":"2010-11-11T12:43:06","date_gmt":"2010-11-11T17:43:06","guid":{"rendered":"http:\/\/www.napoleon.cc\/tips\/2009\/03\/24\/ontario-building-code-and-large-buildings"},"modified":"2021-02-01T12:25:35","modified_gmt":"2021-02-01T12:25:35","slug":"ontario-building-code-and-large-buildings","status":"publish","type":"post","link":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/","title":{"rendered":"Ontario Building Code and Large Buildings"},"content":{"rendered":"\n<p class=\"MsoNormal\">&nbsp;Ontario Building Code and Large Buildings<\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">Most home inspectors take a couple of basic Part 9 Ontario Building Code courses as part of their education. The two courses taught by Georgian College as part of their evening home inspection course&nbsp;covers the basics of the building envelope and structural requirements of buildings under 600 m2, of residential or mercantile occupancies or being three stories or less in building height. &nbsp;Part 3 building inspections require a whole new skill set and qualifications beyond the scope of these part-time evening&nbsp;courses.&nbsp;These courses are typically only available in larger&nbsp;centers such as OBOA teaching facility in Toronto.<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">The Construction Type of buildings is very important when inspecting large buildings. There are two principle types of construction, combustible and non-combustible. Non-combustible construction must meet the criteria set forth in CAN4-S114 \u201cStandard Method of test for Determination of Noncombustibility in Building materials.<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">Combustible construction has a higher flame spread rating and is usually limited to smaller buildings where fires can be more easily controlled by firefighters.<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">There are combustibles that are permitted in combustible construction and they are items like paper covering on gypsum, caulking, window sashes, wood trim and some fixtures.<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">Insulation is an example of a combustible product that must have a thermal barrier installed in order to be used in a building of non-combustible construction. The type of insulation thermal barrier is based on many items such as height of building, sprinklered, location (interior or exterior) and occupancy classification. <\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">Fire separations refer to an assembly that acts as a barrier against the spread of fire or smoke and fire resistance rating refers to the amount of time it withstand before failing. Know what they are and being able to determine the FRR that is required is a very important part of inspecting commercial buildings. Any penetration of a required fire separation must be fire stopped or protected by a rated closure. Every occupancy has different requirements and may or may not require a fire r\u00e9sistance rating. Some fire separations require no FRR and are designed to hold back smoke.<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">Many vertical fire separations are penetrated by horizontal services such as plumbing, heating and electrical. This services must be constructed of approved material, fire stopped, enclosed in FRR shafts, protected by closures or fire stopped if constructed of an approved material.<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">Closures include doors, windows and fire dampers which all must have a FRR required by Ontario Building Code requirements. All hardware installed on closures in fire separations must be approved for use and be listed by recognized agency such as ULC.<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">This is the first in a series of articles being written on Large Buildings as defined by Ministry of Municipal Affairs and Housing and Ontario Building Officials Association. Visit &nbsp;for more information<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-family: 'Times New Roman'; font-size: small;\">&nbsp;<\/span><\/p>\n\n\n\n<p class=\"MsoNormal\"><span style=\"font-size: small; font-family: Times New Roman;\">&nbsp;<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\t\t\t\tPart 3 building inspections require a whole new skill set and qualifications beyond the scope of these part-time evening courses. These courses are typically only available in larger centers such as OBOA teaching facility in Toronto.<\/p>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","wpmdr_menu":2,"wpmdr_menu_extended":{"individualPostRemove":1,"individualPostRemoveDate":1,"individualPostRemoveAuthor":1,"individualPostYoastRemovePublished":1,"individualPostYoastRemoveModified":1},"footnotes":""},"categories":[7],"tags":[],"class_list":["post-217","post","type-post","status-publish","format-standard","hentry","category-commercial-building-inspection"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Ontario Building Code and Large Buildings<\/title>\n<meta name=\"description\" content=\"Ontario Building Code and Large Buildings. The Construction Type of buildings is very important when inspecting large buildings. There are two principle types of construction, combustible and non-combustible. Non-combustible construction must meet the criteria set forth in CAN4-S114 \u201cStandard Method of test for Determination of Noncombustibility in Building materials.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ontario Building Code and Large Buildings\" \/>\n<meta property=\"og:description\" content=\"Ontario Building Code and Large Buildings. The Construction Type of buildings is very important when inspecting large buildings. There are two principle types of construction, combustible and non-combustible. Non-combustible construction must meet the criteria set forth in CAN4-S114 \u201cStandard Method of test for Determination of Noncombustibility in Building materials.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/\" \/>\n<meta property=\"og:site_name\" content=\"Barrie Home Inspector Tips\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Barrie-Home-Inspector-50665344913\/\" \/>\n<meta property=\"article:published_time\" content=\"2010-11-11T17:43:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-01T12:25:35+00:00\" \/>\n<meta name=\"author\" content=\"Roger Frost\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@homeinspection\" \/>\n<meta name=\"twitter:site\" content=\"@homeinspection\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/ontario-building-code-and-large-buildings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/ontario-building-code-and-large-buildings\\\/\"},\"author\":{\"name\":\"Roger Frost\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#\\\/schema\\\/person\\\/b87f223889d916ee48b916377bdeacb0\"},\"headline\":\"Ontario Building Code and Large Buildings\",\"datePublished\":\"2010-11-11T17:43:06+00:00\",\"dateModified\":\"2021-02-01T12:25:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/ontario-building-code-and-large-buildings\\\/\"},\"wordCount\":484,\"articleSection\":[\"Commercial Building Inspection\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/ontario-building-code-and-large-buildings\\\/\",\"url\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/ontario-building-code-and-large-buildings\\\/\",\"name\":\"Ontario Building Code and Large Buildings\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#website\"},\"datePublished\":\"2010-11-11T17:43:06+00:00\",\"dateModified\":\"2021-02-01T12:25:35+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#\\\/schema\\\/person\\\/b87f223889d916ee48b916377bdeacb0\"},\"description\":\"Ontario Building Code and Large Buildings. The Construction Type of buildings is very important when inspecting large buildings. There are two principle types of construction, combustible and non-combustible. Non-combustible construction must meet the criteria set forth in CAN4-S114 \u201cStandard Method of test for Determination of Noncombustibility in Building materials.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/ontario-building-code-and-large-buildings\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/napoleon.cc\\\/tips\\\/ontario-building-code-and-large-buildings\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/ontario-building-code-and-large-buildings\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ontario Building Code and Large Buildings\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#website\",\"url\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/\",\"name\":\"Barrie Home Inspector Tips\",\"description\":\"Home Owner &amp; Home Buyer Tips - Valuable Resource to Help Protect your Home\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/napoleon.cc\\\/tips\\\/#\\\/schema\\\/person\\\/b87f223889d916ee48b916377bdeacb0\",\"name\":\"Roger Frost\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g\",\"caption\":\"Roger Frost\"},\"sameAs\":[\"https:\\\/\\\/www.napoleon.cc\\\/tips\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Ontario Building Code and Large Buildings","description":"Ontario Building Code and Large Buildings. The Construction Type of buildings is very important when inspecting large buildings. There are two principle types of construction, combustible and non-combustible. Non-combustible construction must meet the criteria set forth in CAN4-S114 \u201cStandard Method of test for Determination of Noncombustibility in Building materials.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/","og_locale":"en_US","og_type":"article","og_title":"Ontario Building Code and Large Buildings","og_description":"Ontario Building Code and Large Buildings. The Construction Type of buildings is very important when inspecting large buildings. There are two principle types of construction, combustible and non-combustible. Non-combustible construction must meet the criteria set forth in CAN4-S114 \u201cStandard Method of test for Determination of Noncombustibility in Building materials.","og_url":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/","og_site_name":"Barrie Home Inspector Tips","article_publisher":"https:\/\/www.facebook.com\/Barrie-Home-Inspector-50665344913\/","article_published_time":"2010-11-11T17:43:06+00:00","article_modified_time":"2021-02-01T12:25:35+00:00","author":"Roger Frost","twitter_card":"summary_large_image","twitter_creator":"@homeinspection","twitter_site":"@homeinspection","twitter_misc":{"Written by":false,"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/#article","isPartOf":{"@id":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/"},"author":{"name":"Roger Frost","@id":"https:\/\/napoleon.cc\/tips\/#\/schema\/person\/b87f223889d916ee48b916377bdeacb0"},"headline":"Ontario Building Code and Large Buildings","datePublished":"2010-11-11T17:43:06+00:00","dateModified":"2021-02-01T12:25:35+00:00","mainEntityOfPage":{"@id":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/"},"wordCount":484,"articleSection":["Commercial Building Inspection"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/","url":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/","name":"Ontario Building Code and Large Buildings","isPartOf":{"@id":"https:\/\/napoleon.cc\/tips\/#website"},"datePublished":"2010-11-11T17:43:06+00:00","dateModified":"2021-02-01T12:25:35+00:00","author":{"@id":"https:\/\/napoleon.cc\/tips\/#\/schema\/person\/b87f223889d916ee48b916377bdeacb0"},"description":"Ontario Building Code and Large Buildings. The Construction Type of buildings is very important when inspecting large buildings. There are two principle types of construction, combustible and non-combustible. Non-combustible construction must meet the criteria set forth in CAN4-S114 \u201cStandard Method of test for Determination of Noncombustibility in Building materials.","breadcrumb":{"@id":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/napoleon.cc\/tips\/ontario-building-code-and-large-buildings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/napoleon.cc\/tips\/"},{"@type":"ListItem","position":2,"name":"Ontario Building Code and Large Buildings"}]},{"@type":"WebSite","@id":"https:\/\/napoleon.cc\/tips\/#website","url":"https:\/\/napoleon.cc\/tips\/","name":"Barrie Home Inspector Tips","description":"Home Owner &amp; Home Buyer Tips - Valuable Resource to Help Protect your Home","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/napoleon.cc\/tips\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/napoleon.cc\/tips\/#\/schema\/person\/b87f223889d916ee48b916377bdeacb0","name":"Roger Frost","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7e521c077b1932b64b740ff84ce01034cb97d43562197951c31798d15b242c9a?s=96&d=mm&r=g","caption":"Roger Frost"},"sameAs":["https:\/\/www.napoleon.cc\/tips"]}]}},"_links":{"self":[{"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/posts\/217","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/comments?post=217"}],"version-history":[{"count":0,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/posts\/217\/revisions"}],"wp:attachment":[{"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/media?parent=217"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/categories?post=217"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/napoleon.cc\/tips\/wp-json\/wp\/v2\/tags?post=217"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}